Q: What applications suit the D-curve trip?
A: D-curve is ideal for loads with high inrush currents such as transformers, motors, and capacitive banks.
1 actual photo shown first. Reference images are model-matched and must be confirmed before purchase.
Schneider Electric
M9F43330
Schneider Electric
The Multi9 C60BP miniature circuit breaker provides thermal-magnetic protection for low-voltage distribution applications requiring high inrush tolerance and reliable short-circuit interruption. This 3-pole device is rated 30 A with a D tripping curve, making it suitable for circuits with elevated startup currents. It mounts on DIN rail with a clip-on mechanism and uses a toggle actuator with tunnel terminals for secure copper conductors from 18 to 2 AWG. The breaker achieves a 10 kA interrupting rating at up to 415 VAC per IEC/EN 60947-2 and is UL489 listed at 480Y/277 V, supporting global compliance. It carries IP20/IP40 enclosure ratings and is designed for 50/60 Hz systems. Typical dimensions are 4.06 in H x 2.13 in W x 2.83 in D, with product weight around 0.44 kg. Use it where robust coordination and consistent thermal-magnetic performance are required across commercial OEM panels and multi-standard installations.
Condition, indicative price, stock, and lead time. Confirm current availability via RFQ.
New
Never Used
Used
FNFP
Actual photos when available
Nameplate, condition, and visible wear can be shared before quote when stock photos are not enough.
Test notes for used units
Power-on or function test status is stated when available, with clear condition grading.
Trackable global shipping
DHL, FedEx, UPS, or forwarder options can be quoted with packing photos and tracking details.
Clear DOA boundary
For tested units, quote terms can include 7-day DOA support unless otherwise stated.
Independent sourcing disclaimer
We are not an authorized distributor, reseller, or representative of Siemens, Mitsubishi, Omron, or other manufacturers listed on this site. All product names, trademarks, brands, and logos are the property of their respective owners. Products may be used, refurbished, surplus, or sourced from the secondary market unless otherwise stated.
Prices and stock can change. Submit quantity, required condition, and destination for a current quote.
A: D-curve is ideal for loads with high inrush currents such as transformers, motors, and capacitive banks.
A: 10 kA at up to 415 VAC per IEC/EN 60947-2 and UL489 at 480Y/277 V.
A: Copper conductors from 18 to 2 AWG using tunnel terminals.
A: Clip-on DIN rail mounting for rapid panel installation.
A: Yes, it is rated for 50/60 Hz operation.